Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.18419/opus-3915
Autor(en): Schlipf, David
Trabucchi, Davide
Bischoff, Oliver
Hofsäß, Martin
Mann, Jakob
Mikkelsen, Torben
Rettenmeier, Andreas
Trujillo, Juan José
Kühn, Martin
Titel: Testing of frozen turbulence hypothesis for wind turbine applications with a scanning LIDAR system
Erscheinungsdatum: 2011
Dokumentart: Konferenzbeitrag
Erschienen in: ISARS 2010 : 28-30 June, Paris
URI: http://nbn-resolving.de/urn:nbn:de:bsz:93-opus-85870
http://elib.uni-stuttgart.de/handle/11682/3932
http://dx.doi.org/10.18419/opus-3915
Zusammenfassung: Taylor’s frozen turbulence hypothesis is tested in its applicability for wind turbine applications. In this research full field measurements are performed at a test site for multi-megawatt wind turbines by means of a pulsed LIDAR with a scanning device. The system is installed at the top of the nacelle of a 5MW wind turbine. It provides simultaneous wind speed, with a maximum sampling rate of 5 Hz, at different stations parallel to the mean wind. Measurements in a range between 0.4 and 1.6 rotor diameter are performed following several two and three dimensional trajectories. The spectral characteristics of measurements taken simultaneously at different separation distances are studied. The scanning strategy which maximizes the wavenumber region where results are consistent with Taylor’s hypothesis is assessed. The best results are achieved by a horizontal sliding trajectory with valid wavenumbers up to 0.125 rad/m.
Enthalten in den Sammlungen:06 Fakultät Luft- und Raumfahrttechnik und Geodäsie