Autor(en): | Ma, Zhichao Melde, Kai Athanassiadis, Athanasios G. Schau, Michael Richter, Harald Qiu, Tian Fischer, Peer |
Titel: | Spatial ultrasound modulation by digitally controlling microbubble arrays |
Erscheinungsdatum: | 2020 |
Dokumentart: | Zeitschriftenartikel |
Seiten: | 7 |
Erschienen in: | Nature communications 11 (2020), No. 4537 |
URI: | http://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-132675 http://elib.uni-stuttgart.de/handle/11682/13267 http://dx.doi.org/10.18419/opus-13248 |
ISSN: | 2041-1723 |
Zusammenfassung: | Acoustic waves, capable of transmitting through optically opaque objects, have been widely used in biomedical imaging, industrial sensing and particle manipulation. High-fidelity wave front shaping is essential to further improve performance in these applications. An acoustic analog to the successful spatial light modulator (SLM) in optics would be highly desirable. To date there have been no techniques shown that provide effective and dynamic modulation of a sound wave and which also support scale-up to a high number of individually addressable pixels. In the present study, we introduce a dynamic spatial ultrasound modulator (SUM), which dynamically reshapes incident plane waves into complex acoustic images. Its transmission function is set with a digitally generated pattern of microbubbles controlled by a complementary metal–oxide–semiconductor (CMOS) chip, which results in a binary amplitude acoustic hologram. We employ this device to project sequentially changing acoustic images and demonstrate the first dynamic parallel assembly of microparticles using a SUM. |
Enthalten in den Sammlungen: | 03 Fakultät Chemie |
Dateien zu dieser Ressource:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
s41467-020-18347-2.pdf | 1,59 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons