Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.18419/opus-5688
Langanzeige der Metadaten
DC ElementWertSprache
dc.contributor.authorHeidlauf, Thomasde
dc.contributor.authorRöhrle, Oliverde
dc.date.accessioned2013-11-20de
dc.date.accessioned2016-03-31T10:09:18Z-
dc.date.available2013-11-20de
dc.date.available2016-03-31T10:09:18Z-
dc.date.issued2013de
dc.identifier.other396917291de
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-86696de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/5705-
dc.identifier.urihttp://dx.doi.org/10.18419/opus-5688-
dc.description.abstractAn extensible, flexible, multiscale and multiphysics model for non-isometric skeletal muscle behavior is presented. The skeletal muscle chemoelectromechanical model is based on a bottom-up approach modeling the entire excitation-contraction pathway by strongly coupling a detailed biophysical model of a half-sarcomere to the propagation of action potentials along skeletal muscle fibers, and linking cellular parameters to a transversely isotropic continuum-mechanical constitutive equation describing the overall mechanical behavior of skeletal muscle tissue. Since the multiscale model exhibits separable time scales, a special emphasis is placed on employing computationally efficient staggered solution schemes. Further, the implementation builds on the open-source software library OpenCMISS and uses state-ofthe-art parallelization techniques taking advantage of the unique anatomical fiber architecture of skeletal muscles. OpenCMISS utilizes standardized data structures for geometrical aspects (FieldML) and cellular models (CellML). Both standards are designed to allow for a maximum on flexibility, reproducibility, and extensibility. The results demonstrate the model´s capability of simulating different aspects of non-isometric muscle contraction and to efficiently simulate the chemoelectromechanical behavior in complex skeletal muscles such as the tibialis anterior muscle.en
dc.language.isoende
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.subject.classificationSkelettmuskel , Finite-Elemente-Methodede
dc.subject.ddc620de
dc.subject.otherChemoelectromechanics , skeletal muscle model , Finite Element Method , 0D-1D-3D coupling , staggered grids , data structure , parallelizationen
dc.titleModeling the chemoelectromechanical behavior of skeletal muscle using the parallel open-source software library OpenCMISSen
dc.typearticlede
dc.date.updated2015-01-20de
ubs.fakultaetInterfakultäre Einrichtungende
ubs.fakultaetFakultät Bau- und Umweltingenieurwissenschaftende
ubs.institutStuttgart Research Centre for Simulation Technology (SRC SimTech)de
ubs.institutInstitut für Mechanik (Bauwesen)de
ubs.opusid8669de
ubs.publikation.sourceComputational and mathematical methods in medicine (2013), article ID 517287. URL http://dx.doi.org/10.1155/2013/517287de
ubs.publikation.typZeitschriftenartikelde
Enthalten in den Sammlungen:11 Interfakultäre Einrichtungen

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
final_printed.pdf2,74 MBAdobe PDFÖffnen/Anzeigen


Alle Ressourcen in diesem Repositorium sind urheberrechtlich geschützt.