Repository logoOPUS - Online Publications of University Stuttgart
de / en
Log In
New user? Click here to register.Have you forgotten your password?
Communities & Collections
All of DSpace
  1. Home
  2. Browse by Author

Browsing by Author "Prass, Sebastian"

Filter results by typing the first few letters
Now showing 1 - 3 of 3
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    ItemOpen Access
    CO and H2S in H2: contamination, recovery and mitigation strategies in PEMFCs with ultra-low Pt loaded anode electrodes
    (2024) Prass, Sebastian; Friedrich, K. Andreas (Prof. Dr. rer. nat.)
    Einige der größten Hürden für die Kommerzialisierung von Fahrzeugen mit Brennstoffzellenantrieb (engl. Proton Exchange Membrane Fuel Cell, PEMFC) sind die Kosten und Lebensdauer der Systeme, sowie die fehlende Infrastruktur, die den Wasserstoff (H2) bereitstellt. Zur Verringerung der PEMFC-Kosten ist eine Reduktion des Gehalts an Katalysatoren der Platin (Pt)-Gruppe nötig, was jedoch durch Vergiftungsmechanismen erschwert wird, deren Wirkung bei niedrigeren Pt-Beladungen pro aktiver Fläche ([µgPt/cm²]) zunimmt. Verunreinigungen im H2, die durch kostenintensive Reinigungsverfahren herausgefiltert werden, beeinträchtigen die PEMFC-Leistung und Lebensdauer. Sind Kontaminations- und Erholungsmechanismen bekannt, können Betriebsweisen angepasst und der Katalysatorgehalt einerseits verringert, sowie die Herstellung und Aufreinigung des H2 andererseits kosteneffizienter gestaltet werden. Diese Dissertation untersucht daher die Auswirkung einer Verringerung der Platinbeladung der Anodenelektrode auf die Toleranz gegenüber Kohlenmonoxid (CO) und Schwefelwasserstoff (H2S) im H2 anhand von Einzelzellen unter Verwendung klassischer elektrochemischer Charakterisierungsverfahren. Zunächst ist die Charakterisierung niedrig beladener Elektroden per Zyklovoltammetrie (engl. Cyclic Voltammetry, CV) durch Artefakte erschwert, die normalerweise bei höheren Beladungen (>100 µgPt/cm²) nicht auftreten. Bei niedrigen Beladungen (<50 µgPt/cm²) kann es zu einer spontanen Oxidation von angesammeltem Permeat-Wasserstoff während des kathodischen CV-Vorschubs kommen, was den Pt-Oxid-Reduktionsstrom überlappt und die Bestimmung der aktiven Fläche (engl. Electrochemically Active Surface Area, ECSA) beeinträchtigt. Werden PEMFCs mit gering beladenen Anodenelektroden (<25 µgPt/cm²) und H2 betrieben, der CO in Konzentrationen enthält, die gemäß H2-Qualitätsstandard ISO 14687 zulässig sind, kommt es zu inakzeptablen Spannungsabfällen von bis zu 40%. Dies deutet darauf hin, dass die CO-Toleranz des Katalysators verbessert, oder der ISO-Grenzwert für CO verringert werden sollte. Ist H2S in Konzentrationen gemäß ISO 14687 im H2 enthalten, kommt es während chronoamperometrischer Tests zu Spannungseinbrüchen, die bei niedrig beladenen Elektroden Schwefeldosisabhängig früher auftreten. Andererseits können sich PEMFCs durch Stopp/Start (engl. Shut-Down/Start-Up, SD/SU)-Prozeduren von Schwefelvergiftungen erholen. Gemeinsam mit den erst nach Dutzenden Stunden auftretenden Spannungseinbrüchen wirft diese Erholung durch SD/SUs die Frage auf, ob der ISO-Grenzwert für Schwefelspezies einer Anpassung bedarf. Eine Beschichtung des Pt-Katalysators in der Anodenelektrode mit einer Siliziumoxidschicht (SiO2-Pt/C) verbessert die Leistung und Toleranz der PEMFC beim Betrieb mit reinem und H2S-kontaminiertem H2, verschlechtert jedoch deren CO-Toleranz. Während die Verbesserung der Leistung und H2S-Toleranz auf Einflüsse des SiO2 auf Wassermanagement und Mobilität oxidierter Schwefelspezies zurückzuführen ist, steht die Verschlechterung der CO-Toleranz im Zusammenhang mit erschwerter Bildung und Mobilität der OH-Gruppen, die für die CO-Oxidation notwendig und in erhöhten Potentialen für CO-Oxidation sichtbar sind.
  • Thumbnail Image
    ItemOpen Access
    Hydrogen oxidation artifact during platinum oxide reduction in cyclic voltammetry analysis of low-loaded PEMFC electrodes
    (2020) Prass, Sebastian; St-Pierre, J.; Klingele, Matthias; Friedrich, K. Andreas; Zamel, Nada
    An artifact appearing during the cathodic transient of cyclic voltammograms (CVs) of low-loaded platinum on carbon (Pt/C) electrodes in proton exchange membrane fuel cells (PEMFCs) was examined. The artifact appears as an oxidation peak overlapping the reduction peak associated to the reduction of platinum oxide (PtOx). By varying the nitrogen (N2) purge in the working electrode (WE), gas pressures in working and counter electrode, upper potential limits and scan rates of the CVs, the artifact magnitude and potential window could be manipulated. From the results, the artifact is assigned to crossover hydrogen (H2X) accumulating in the WE, once the electrode is passivated towards hydrogen oxidation reaction (HOR) due to PtOx coverage. During the cathodic CV transient, PtOx is reduced and HOR spontaneously occurs with the accumulated H2X, resulting in the overlap of the PtOx reduction with the oxidation peak. This feature is expected to occur predominantly in CV analysis of low-loaded electrodes made of catalyst material, whose oxide is inactive towards HOR. Further, it is only measurable while the N2 purge of the WE is switched off during the CV measurement. For higher loaded electrodes, the artifact is not observed as the electrocatalysts are not fully inactivated towards HOR due to incomplete oxide coverage, and/or the currents associated with the oxide reduction are much larger than the spontaneous HOR of accumulated H2X. However, owing to the forecasted reduction in noble metal loadings of catalyst in PEMFCs, this artifact is expected to be observed more often in the future.
  • Thumbnail Image
    ItemOpen Access
    Tolerance of silicon oxide‐coated Pt/C catalyst toward CO and H2S contamination in hydrogen for proton exchange membrane fuel cells
    (2023) Prass, Sebastian; Nerlich, Leon; Singh, Rajveer; Godoy, Andres O.; Jankovic, Jasna; Friedrich, K. Andreas; Zamel, Nada
    Platinum on graphitized low surface area carbon (Pt/C) is coated with a silicon oxide thin film and is employed as anode catalyst to manipulate the tolerance of proton exchange membrane fuel cells toward carbon monoxide and hydrogen sulfide contamination. The SiO2 coating, prepared by successive hydrolysis of 3-aminopropyl-triethoxisilane and tetraethoxysilane, forms clusters in proximity to Pt in sizes comparable to the catalyst particles, leaving most of the carbon surfaces free. The performance with and without CO is investigated in situ at relative humidities (RH) of 100%, 70%, and 40%. When operated with neat hydrogen, SiO2-Pt/C shows marginally better performance owing to an improved protonic conduction due to the water retaining hydrophilic SiO2. Upon operation with CO-contaminated fuel, the SiO2-Pt/C performs worse than that of Pt/C particularly at high RH. CO stripping measurements reveal an increase in CO oxidation potential for the SiO2-Pt/C, suggesting an increased CO coverage and consequently higher anode overpotentials during operation with CO-contaminated fuel. Upon operation with H2S in the fuel, the SiO2 coating extends the lifetime until the cell voltage broke down, which is attributed to the enhanced water retention due to SiO2 and the solubility of sulfuric species.
OPUS
  • About OPUS
  • Publish with OPUS
  • Legal information
DSpace
  • Cookie settings
  • Privacy policy
  • Send Feedback
University Stuttgart
  • University Stuttgart
  • University Library Stuttgart