Repository logoOPUS - Online Publications of University Stuttgart
de / en
Log In
New user? Click here to register.Have you forgotten your password?
Communities & Collections
All of DSpace
  1. Home
  2. Browse by Author

Browsing by Author "Schalk, Marco"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    ItemOpen Access
    Influence of exoskeleton use on Cardiac Index
    (2022) Schalk, Marco; Schalk, Ines; Bauernhansl, Thomas; Siegert, Jörg; Schneider, Urs
    This study aims to assess the whole-body physiological effects of wearing an exoskeleton during a one-hour standardized work task, utilizing the Cardiac Index (CI) as the target parameter. N = 42 young and healthy subjects with welding experience took part in the study. The standardized and abstracted one-hour workflow consists of simulated welding and grinding in constrained body positions and was completed twice by each subject, with and without an exoskeleton, in a randomized order. The CI was measured by Impedance Cardiography (ICG), an approved medical method. The difference between the averaged baseline measurement and the averaged last 10 min was computed for the conditions with and without an exoskeleton for each subject to result in ∆CIwithout exo and ∆CIwith exo. A significant difference between the conditions with and without an exoskeleton was found, with the reduction in CI when wearing an exoskeleton amounting to 10.51%. This result corresponds to that of previous studies that analyzed whole-body physiological load by means of spiroergometry. These results suggest a strong positive influence of exoskeletons on CI and, therefore, physiological load. At the same time, they also support the hypothesis that ICG is a suitable measurement instrument to assess these effects.
  • Thumbnail Image
    ItemOpen Access
    Investigation of possible effects of wearing exoskeletons during welding on heart rate
    (2022) Schalk, Marco; Schalk, Ines; Bauernhansl, Thomas; Siegert, Jörg; Schneider, Urs
    This study aims to investigate the possible effects of wearing exoskeletons during welding on heart rate. Additionally, the validity of a measuring instrument for determining acute heart rate is to be assessed. N = 15 young healthy subjects with welding experience took part in the study. The study design defines a one-hour workflow that abstracts welding and grinding tasks. The sequence is based on the internationally recognized standard DIN EN ISO 9606-1 and reproduces authentic work sequences in constrained body positions. Each subject completed the workflow once with and once without an exoskeleton. Recorded measures were the heart rates measured by a wrist-worn smartwatch and by Impedance Cardiography (ICG). The average heart rate shows no statistically significant differences in the measurement series with and without exoskeletons. The temporal variation of the heart rate shows a statistically significant influence of wearing exoskeletons and provides a moderate to strong effect, corresponding to a Cohens d of d = 0.78. Only 28.57% of all data series obtained with a smartwatch were equivalent to ICG-data after analysis with t-test, Pearson’s correlation, and orthogonal regression. Using averaged heart rates to assess exoskeleton effects is not a suitable measure. A trend analysis using linear regression shows moderate to strong statistically significant effects in the time course of heart rates and provides an approach to evaluate exoskeleton-induced effects.
OPUS
  • About OPUS
  • Publish with OPUS
  • Legal information
DSpace
  • Cookie settings
  • Privacy policy
  • Send Feedback
University Stuttgart
  • University Stuttgart
  • University Library Stuttgart