Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.18419/opus-13584
Autor(en): Lakhani, Hitesh
Hofmann, Jan
Titel: Concrete cone failure of post installed fasteners during fire
Erscheinungsdatum: 2023
Dokumentart: Zeitschriftenartikel
Seiten: 373-380
Erschienen in: ce/papers 6 (2023), S. 373-380
URI: http://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-136036
http://elib.uni-stuttgart.de/handle/11682/13603
http://dx.doi.org/10.18419/opus-13584
ISSN: 2509-7075
Zusammenfassung: The fire resistance of fasteners needs to be verified for all failure modes applicable at ambient conditions. Generally, in most cases, for unprotected fasteners loaded in tension, steel failure mode is decisive. But for fasteners made of stainless steel and/or larger (bolt) sizes, concrete cone failure may be the decisive failure mode for small anchorage depths. Due to practical difficulties associated with loading an anchor during a fire test, very limited experimental data is available in literature and that to for relatively small embedment depths. The paper presents the results (6 nos) of the fire tests conducted on expansion anchors (made of stainless steel) with sizes M12 (hef = 70 mm) and M20 (hef = 100 mm). Moreover, the paper also compares the reduction in the concrete cone capacity with exposure duration, predicted as per the current design guidelines and the new set of experimental data obtained in this study.
Enthalten in den Sammlungen:02 Fakultät Bau- und Umweltingenieurwissenschaften

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
CEPA_CEPA1920.pdf703,69 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons