Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.18419/opus-8875
Langanzeige der Metadaten
DC ElementWertSprache
dc.contributor.authorTenbohlen, Stefan-
dc.contributor.authorJovalekic, Mark-
dc.contributor.authorBates, Lisa-
dc.contributor.authorSzewczyk, Radoslaw-
dc.date.accessioned2016-09-26T11:37:33Z-
dc.date.available2016-09-26T11:37:33Z-
dc.date.issued2011de
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-88925de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/8892-
dc.identifier.urihttp://dx.doi.org/10.18419/opus-8875-
dc.description.abstractA method developed for establishing moisture equilibrium curves for any combination of liquid and solid insulation is presented in this paper. Moisture saturation curves for natural and synthetic esters have been presented in the temperature range up to 140°C together with curve for mineral oil as a reference. Sorption isotherms have been established for cellulose based and aramid fiber based materials. Eventually, the moisture equilibrium diagrams have been created for given combinations of solids and liquids. Moisture equilibrium curves have been created for combinations of mineral oil and ester fluids with aramid fiber based papers and boards, as they are commonly used in alternative insulation systems. The new curves give information on moisture distribution within the alternative insulation systems and may be critical for setting the material choices, design rules and maintenance guidelines for equipment using these combinations. Only then the materials could be used optimally and their specific characteristics could bring full range of benefits to the equipment. Also the condition monitoring and diagnostics for the purpose of asset management will be more reliable when these new characteristics are used. It has been observed that insulation components made of aramid insulation may have lower water content comparing to cellulose based conventional materials at the same water content measured in dielectric liquid. As a result, the performance of aramid insulation components may be less sensitive to moisture in oil (aging processes, dielectric strength, partial discharge performance) comparing to conventional systems based on cellulose.en
dc.language.isoende
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.subject.ddc621.3de
dc.titleWater saturation limits and moisture equilibrium curves of alternative insulation systemsen
dc.typeconferenceObjectde
ubs.fakultaetInformatik, Elektrotechnik und Informationstechnikde
ubs.fakultaetFakultätsübergreifend / Sonstige Einrichtungde
ubs.institutInstitut für Energieübertragung und Hochspannungstechnikde
ubs.institutFakultätsübergreifend / Sonstige Einrichtungde
ubs.konferenznameCIGRE SC A2 & D1 Joint Colloquium (2011, Kyoto)de
ubs.publikation.noppnyesde
ubs.publikation.seiten7de
ubs.publikation.typKonferenzbeitragde
Enthalten in den Sammlungen:05 Fakultät Informatik, Elektrotechnik und Informationstechnik

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
CIGRE Kyoto - Moisture Equilibrium Curves.pdf1,81 MBAdobe PDFÖffnen/Anzeigen