Comparison of measured and simulated structural loads of an offshore wind turbine at Alpha Ventus

Thumbnail Image

Date

2016

Journal Title

Journal ISSN

Volume Title

Publisher

Abstract

A comparison of fatigue and extreme loads from simulations with full-scale measurements collected over a period of ten months in the offshore test field, Alpha Ventus, is presented in this paper. There are two goals of this study: (1) to check if the measured range of fatigue and extreme loads can be captured correctly by simulations when the variations of relevant environmental parameters are taken into account; and (2) to investigate if measured extreme loads can be reproduced by simulations when ten-minute averages of the environmental parameters are used. The results show a good overall match of loads when the variation of environmental parameters is considered but an insufficient match when the events of maximum load occurrence are compared.

Description

Keywords

Citation

Endorsement

Review

Supplemented By

Referenced By