Degradation rate location dependency of photovoltaic systems

dc.contributor.authorFrick, Alexander
dc.contributor.authorMakrides, George
dc.contributor.authorSchubert, Markus
dc.contributor.authorSchlecht, Matthias
dc.contributor.authorGeorghiou, George E.
dc.date.accessioned2023-08-10T12:43:37Z
dc.date.available2023-08-10T12:43:37Z
dc.date.issued2020
dc.date.updated2021-01-08T03:32:09Z
dc.description.abstractA main challenge towards ensuring improved lifetime performance and reduction of financial risks of photovoltaic (PV) technologies remains the accurate degradation quantification of field systems and the dependency of this performance loss rate to climatic conditions. The purpose of this study is to address these technological issues by presenting a unified methodology for accurately calculating the degradation rate (𝑅𝐷) of PV systems and provide evidence that degradation mechanisms are location dependent. The method followed included the application of data inference and time series analytics, in the scope of comparing the long-term 𝑅𝐷 of different crystalline Silicon (c-Si) PV systems, installed at different climatic locations. The application of data quality and filtering steps ensured data fidelity for the 𝑅𝐷 analysis. The yearly 𝑅𝐷 results demonstrated that the adopted time series analytical techniques converged after 7 years and were in close agreement to the degradation results obtained from indoor standardized procedures. Finally, the initial hypothesis that the 𝑅𝐷 is location dependent was verified, since the multicrystalline silicon (multi-c-Si) systems at the warm climatic region exhibited higher degradation compared to the respective systems at the moderate climate. For the investigated monocrystalline silicon (mono-c-Si) systems the location-dependency is also affected by the manufacturing technology.en
dc.identifier.issn1996-1073
dc.identifier.other1858240212
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-134133de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/13413
dc.identifier.urihttp://dx.doi.org/10.18419/opus-13394
dc.language.isoende
dc.relation.uridoi:10.3390/en13246751de
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/de
dc.subject.ddc333.7de
dc.titleDegradation rate location dependency of photovoltaic systemsen
dc.typearticlede
ubs.fakultaetInterfakultäre Einrichtungende
ubs.fakultaetFakultätsübergreifend / Sonstige Einrichtungde
ubs.institutStuttgart Research Centre of Photonic Engineering (SCoPE)de
ubs.institutFakultätsübergreifend / Sonstige Einrichtungde
ubs.publikation.seiten20de
ubs.publikation.sourceEnergies 13 (2020), No. 6751de
ubs.publikation.typZeitschriftenartikelde

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
energies-13-06751-v2.pdf
Size:
3.82 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.39 KB
Format:
Plain Text
Description: