Investigation of possible effects of wearing exoskeletons during welding on heart rate

dc.contributor.authorSchalk, Marco
dc.contributor.authorSchalk, Ines
dc.contributor.authorBauernhansl, Thomas
dc.contributor.authorSiegert, Jörg
dc.contributor.authorSchneider, Urs
dc.date.accessioned2024-03-15T09:15:48Z
dc.date.available2024-03-15T09:15:48Z
dc.date.issued2022de
dc.date.updated2023-11-14T00:11:56Z
dc.description.abstractThis study aims to investigate the possible effects of wearing exoskeletons during welding on heart rate. Additionally, the validity of a measuring instrument for determining acute heart rate is to be assessed. N = 15 young healthy subjects with welding experience took part in the study. The study design defines a one-hour workflow that abstracts welding and grinding tasks. The sequence is based on the internationally recognized standard DIN EN ISO 9606-1 and reproduces authentic work sequences in constrained body positions. Each subject completed the workflow once with and once without an exoskeleton. Recorded measures were the heart rates measured by a wrist-worn smartwatch and by Impedance Cardiography (ICG). The average heart rate shows no statistically significant differences in the measurement series with and without exoskeletons. The temporal variation of the heart rate shows a statistically significant influence of wearing exoskeletons and provides a moderate to strong effect, corresponding to a Cohens d of d = 0.78. Only 28.57% of all data series obtained with a smartwatch were equivalent to ICG-data after analysis with t-test, Pearson’s correlation, and orthogonal regression. Using averaged heart rates to assess exoskeleton effects is not a suitable measure. A trend analysis using linear regression shows moderate to strong statistically significant effects in the time course of heart rates and provides an approach to evaluate exoskeleton-induced effects.en
dc.description.sponsorshipDeutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany’s Excellence Strategyde
dc.description.sponsorshipUniversity of Stuttgart IFF and Fraunhofer IPA, Stuttgartde
dc.identifier.issn2673-9488
dc.identifier.other1883643600
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-140807de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/14080
dc.identifier.urihttp://dx.doi.org/10.18419/opus-14061
dc.language.isoende
dc.relation.uridoi:10.3390/physiologia2030009de
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/de
dc.subject.ddc620de
dc.titleInvestigation of possible effects of wearing exoskeletons during welding on heart rateen
dc.typearticlede
ubs.fakultaetKonstruktions-, Produktions- und Fahrzeugtechnikde
ubs.fakultaetExterne wissenschaftliche Einrichtungende
ubs.institutInstitut für Industrielle Fertigung und Fabrikbetriebde
ubs.institutFraunhofer Institut für Produktionstechnik und Automatisierung (IPA)de
ubs.publikation.seiten94-108de
ubs.publikation.sourcePhysiologia 2 (2022), S. 94-108de
ubs.publikation.typZeitschriftenartikelde

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
physiologia-02-00009.pdf
Size:
5.02 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.3 KB
Format:
Item-specific license agreed upon to submission
Description: