02 Fakultät Bau- und Umweltingenieurwissenschaften

Permanent URI for this collectionhttps://elib.uni-stuttgart.de/handle/11682/3

Browse

Search Results

Now showing 1 - 10 of 26
  • Thumbnail Image
    ItemOpen Access
    Linking cortex and contraction : integrating models along the corticomuscular pathway
    (2023) Haggie, Lysea; Schmid, Laura; Röhrle, Oliver; Besier, Thor; McMorland, Angus; Saini, Harnoor
    Computational models of the neuromusculoskeletal system provide a deterministic approach to investigate input-output relationships in the human motor system. Neuromusculoskeletal models are typically used to estimate muscle activations and forces that are consistent with observed motion under healthy and pathological conditions. However, many movement pathologies originate in the brain, including stroke, cerebral palsy, and Parkinson’s disease, while most neuromusculoskeletal models deal exclusively with the peripheral nervous system and do not incorporate models of the motor cortex, cerebellum, or spinal cord. An integrated understanding of motor control is necessary to reveal underlying neural-input and motor-output relationships. To facilitate the development of integrated corticomuscular motor pathway models, we provide an overview of the neuromusculoskeletal modelling landscape with a focus on integrating computational models of the motor cortex, spinal cord circuitry, α-motoneurons  and skeletal muscle in regard to their role in generating voluntary muscle contraction. Further, we highlight the challenges and opportunities associated with an integrated corticomuscular pathway model, such as challenges in defining neuron connectivities, modelling standardisation, and opportunities in applying models to study emergent behaviour. Integrated corticomuscular pathway models have applications in brain-machine-interaction, education, and our understanding of neurological disease.
  • Thumbnail Image
    ItemOpen Access
    Determination of muscle shape deformations of the tibialis anterior during dynamic contractions using 3D ultrasound
    (2024) Sahrmann, Annika S.; Vosse, Lukas; Siebert, Tobias; Handsfield, Geoffrey G.; Röhrle, Oliver
    Purpose: In this paper, we introduce a novel method for determining 3D deformations of the human tibialis anterior (TA) muscle during dynamic movements using 3D ultrasound. Materials and Methods: An existing automated 3D ultrasound system is used for data acquisition, which consists of three moveable axes, along which the probe can move. While the subjects perform continuous plantar- and dorsiflexion movements in two different controlled velocities, the ultrasound probe sweeps cyclically from the ankle to the knee along the anterior shin. The ankle joint angle can be determined using reflective motion capture markers. Since we considered the movement direction of the foot, i.e., active or passive TA, four conditions occur: slow active, slow passive, fast active, fast passive. By employing an algorithm which defines ankle joint angle intervals, i.e., intervals of range of motion (ROM), 3D images of the volumes during movement can be reconstructed. Results: We found constant muscle volumes between different muscle lengths, i.e., ROM intervals. The results show an increase in mean cross-sectional area (CSA) for TA muscle shortening. Furthermore, a shift in maximum CSA towards the proximal side of the muscle could be observed for muscle shortening. We found significantly different maximum CSA values between the fast active and all other conditions, which might be caused by higher muscle activation due to the faster velocity. Conclusion: In summary, we present a method for determining muscle volume deformation during dynamic contraction using ultrasound, which will enable future empirical studies and 3D computational models of skeletal muscles.
  • Thumbnail Image
    ItemOpen Access
    Effect of neglecting passive spinal structures : a quantitative investigation using the forward-dynamics and inverse-dynamics musculoskeletal approach
    (2023) Meszaros-Beller, Laura; Hammer, Maria; Schmitt, Syn; Pivonka, Peter
    Inverse-dynamics (ID) analysis is an approach widely used for studying spine biomechanics and the estimation of muscle forces. Despite the increasing structural complexity of spine models, ID analysis results substantially rely on accurate kinematic data that most of the current technologies are not capable to provide. For this reason, the model complexity is drastically reduced by assuming three degrees of freedom spherical joints and generic kinematic coupling constraints. Moreover, the majority of current ID spine models neglect the contribution of passive structures. The aim of this ID analysis study was to determine the impact of modelled passive structures (i.e., ligaments and intervertebral discs) on remaining joint forces and torques that muscles must balance in the functional spinal unit. For this purpose, an existing generic spine model developed for the use in the demoa software environment was transferred into the musculoskeletal modelling platform OpenSim. The thoracolumbar spine model previously used in forward-dynamics (FD) simulations provided a full kinematic description of a flexion-extension movement. By using the obtained in silico kinematics, ID analysis was performed. The individual contribution of passive elements to the generalised net joint forces and torques was evaluated in a step-wise approach increasing the model complexity by adding individual biological structures of the spine. The implementation of intervertebral discs and ligaments has significantly reduced compressive loading and anterior torque that is attributed to the acting net muscle forces by −200% and −75%, respectively. The ID model kinematics and kinetics were cross-validated against the FD simulation results. This study clearly shows the importance of incorporating passive spinal structures on the accurate computation of remaining joint loads. Furthermore, for the first time, a generic spine model was used and cross-validated in two different musculoskeletal modelling platforms, i.e., demoa and OpenSim, respectively. In future, a comparison of neuromuscular control strategies for spinal movement can be investigated using both approaches.
  • Thumbnail Image
    ItemOpen Access
    The structural and mechanical basis for passive‐hydraulic pine cone actuation
    (2022) Eger, Carmen J.; Horstmann, Martin; Poppinga, Simon; Sachse, Renate; Thierer, Rebecca; Nestle, Nikolaus; Bruchmann, Bernd; Speck, Thomas; Bischoff, Manfred; Rühe, Jürgen
    The opening and closing of pine cones is based on the hygroscopic behavior of the individual seed scales around the cone axis, which bend passively in response to changes in environmental humidity. Although prior studies suggest a bilayer architecture consisting of lower actuating (swellable) sclereid and upper restrictive (non‐ or lesser swellable) sclerenchymatous fiber tissue layers to be the structural basis of this behavior, the exact mechanism of how humidity changes are translated into global movement are still unclear. Here, the mechanical and hydraulic properties of each structural component of the scale are investigated to get a holistic picture of their functional interplay. Measurements of the wetting behavior, water uptake, and mechanical measurements are used to analyze the influence of hydration on the different tissues of the cone scales. Furthermore, their dimensional changes during actuation are measured by comparative micro‐computed tomography (µ‐CT) investigations of dry and wet scales, which are corroborated and extended by 3D‐digital image correlation‐based displacement and strain analyses, biomechanical testing of actuation force, and finite element simulations. Altogether, a model allowing a detailed mechanistic understanding of pine cone actuation is developed, which is a prime concept generator for the development of biomimetic hygromorphic systems.
  • Thumbnail Image
    ItemOpen Access
    Variations in muscle activity and exerted torque during temporary blood flow restriction in healthy individuals
    (2021) Gizzi, Leonardo; Yavuz, Utku Ş.; Hillerkuss, Dominic; Geri, Tommaso; Gneiting, Elena; Domeier, Franziska; Schmitt, Syn; Röhrle, Oliver
    Recent studies suggest that transitory blood flow restriction (BFR) may improve the outcomes of training from anatomical (hypertrophy) and neural control perspectives. Whilst the chronic consequences of BFR on local metabolism and tissue adaptation have been extensively investigated, its acute effects on motor control are not yet fully understood. In this study, we compared the neuromechanical effects of continuous BFR against non-restricted circulation (atmospheric pressure-AP), during isometric elbow flexions. BFR was achieved applying external pressure either between systolic and diastolic (lower pressure-LP) or 1.3 times the systolic pressure (higher pressure-HP). Three levels of torque (15, 30, and 50% of the maximal voluntary contraction-MVC) were combined with the three levels of pressure for a total of 9 (randomized) test cases. Each condition was repeated 3 times. The protocol was administered to 12 healthy young adults. Neuromechanical measurements (torque and high-density electromyography-HDEMG) and reported discomfort were used to investigate the response of the central nervous system to BFR. The investigated variables were: root mean square (RMS), and area under the curve in the frequency domain-for the torque, and average RMS, median frequency and average muscle fibres conduction velocity-for the EMG. The discomfort caused by BFR was exacerbated by the level of torque and accumulated over time. The torque RMS value did not change across conditions and repetitions. Its spectral content, however, revealed a decrease in power at the tremor band (alpha-band, 5-15 Hz) which was enhanced by the level of pressure and the repetition number. The EMG amplitude showed no differences whilst the median frequency and the conduction velocity decreased over time and across trials, but only for the highest levels of torque and pressure. Taken together, our results show strong yet transitory effects of BFR that are compatible with a motor neuron pool inhibition caused by increased activity of type III and IV afferences, and a decreased activity of spindle afferents. We speculate that a compensation of the central drive may be necessary to maintain the mechanical output unchanged, despite disturbances in the afferent volley to the motor neuron pool.
  • Thumbnail Image
    ItemOpen Access
    Editorial - somatosensory integration in human movement : perspectives for neuromechanics, modelling and rehabilitation
    (2021) Gizzi, Leonardo; Vujaklija, Ivan; Sartori, Massimo; Röhrle, Oliver; Severini, Giacomo
  • Thumbnail Image
    ItemOpen Access
    The use of nonnormalized surface EMG and feature inputs for LSTM-based powered ankle prosthesis control algorithm development
    (2023) Keleş, Ahmet Doğukan; Türksoy, Ramazan Tarık; Yucesoy, Can A.
    Advancements in instrumentation support improved powered ankle prostheses hardware development. However, control algorithms have limitations regarding number and type of sensors utilized and achieving autonomous adaptation, which is key to a natural ambulation. Surface electromyogram (sEMG) sensors are promising. With a minimized number of sEMG inputs an economic control algorithm can be developed, whereas limiting the use of lower leg muscles will provide a practical algorithm for both ankle disarticulation and transtibial amputation. To determine appropriate sensor combinations, a systematic assessment of the predictive success of variations of multiple sEMG inputs in estimating ankle position and moment has to conducted. More importantly, tackling the use of nonnormalized sEMG data in such algorithm development to overcome processing complexities in real-time is essential, but lacking. We used healthy population level walking data to (1) develop sagittal ankle position and moment predicting algorithms using nonnormalized sEMG, and (2) rank all muscle combinations based on success to determine economic and practical algorithms. Eight lower extremity muscles were studied as sEMG inputs to a long-short-term memory (LSTM) neural network architecture: tibialis anterior (TA), soleus (SO), medial gastrocnemius (MG), peroneus longus (PL), rectus femoris (RF), vastus medialis (VM), biceps femoris (BF) and gluteus maximus (GMax). Five features extracted from nonnormalized sEMG amplitudes were used: integrated EMG (IEMG), mean absolute value (MAV), Willison amplitude (WAMP), root mean square (RMS) and waveform length (WL). Muscle and feature combination variations were ranked using Pearson’s correlation coefficient (r > 0.90 indicates successful correlations), the root-mean-square error and one-dimensional statistical parametric mapping between the original data and LSTM response. The results showed that IEMG+WL yields the best feature combination performance. The best performing variation was MG + RF + VM (rposition = 0.9099 and rmoment = 0.9707) whereas, PL (rposition = 0.9001, rmoment = 0.9703) and GMax+VM (rposition = 0.9010, rmoment = 0.9718) were distinguished as the economic and practical variations, respectively. The study established for the first time the use of nonnormalized sEMG in control algorithm development for level walking.
  • Thumbnail Image
    ItemOpen Access
    Numerical study of the stress state on the oral mucosa and abutment tooth upon insertion of partial dentures in the mandible
    (2022) Ramakrishnan, Anantha Narayanan; Röhrle, Oliver; Ludtka, Christopher; Varghese, Roshan; Koehler, Josephine; Kiesow, Andreas; Schwan, Stefan
    The introduction of a removable partial denture onto the dental arch significantly influences the mechanical stress characteristics of both the jawbone and oral mucosa. The aim of this study was to analyze the stress state caused by biting forces upon insertion of partial dentures into the assembly, and to understand the influence of the resulting contact pressure on its retention behavior. For this purpose, a numerical model of a removable partial denture is proposed based on 3D models developed using computer tomography data of the jawbone and the removable partial denture. The denture system rests on the oral mucosa surface and three abutment teeth. The application of bite forces on the denture generated a stick condition on the loaded regions of the denture‐oral mucosa interface, which indicates positive retention of the denture onto the oral mucosa surface. Slip and negative retention were observed in the regions of the contact space that were not directly loaded. The contact pressures observed in the regions of the oral mucosa in contact with the denture were below the clinical pressure pain threshold value for soft tissue, which potentially lowers the risk of pain being experienced by denture users. Further, the variation of the retention behavior and contact pressures across different regions of the denture assembly was observed. Thus, there is a need for adhesives or restraining mechanisms for the denture system in order to avoid bending and deformation of sections of the denture as a consequence of the applied bite force.
  • Thumbnail Image
    ItemOpen Access
    Mapping the role of oral cavity physiological factors into the viscoelastic model of denture adhesives for numerical implementation
    (2023) Ramakrishnan, Anantha Narayanan; Röhrle, Oliver; Ludtka, Christopher; Koehler, Josephine; Kiesow, Andreas; Schwan, Stefan
    Physiological parameters of the oral cavity have a profound impact on any restorative solutions designed for edentulous patients including denture adhesives. This study aims to mathematically quantify the influence of three such variables, namely: the temperature, pH, and the swelling of such adhesives under the influence of saliva on its mechanical behavior. The mathematical quantification is further aimed to implement a material model for such adhesives which considers the impact of such physiological factors. The denture adhesive is experimentally investigated by means of rheological steady state frequency sweep tests to obtain the relaxation spectrum of the material. The relaxation behavior is measured for a wide range of oral cavity temperatures and pH. Also, the adhesive is hydrated and upon swelling to different levels again tested to understand the impact of swelling on the mechanical behavior. The experimentally measured continuous relaxation spectrum is modeled as a viscoelastic material using a discrete set of points based on the Prony series discretization technique. The relaxation spectrums for various temperatures are compared and the possibility of a time-temperature superposition is explored for the model. Similarly, the measured values of Storage and loss modulus are investigated to understand the role of pH and swelling. The results in this study clearly indicated a horizontal shift in the relaxation behavior with increase in temperature. And hence, the time-temperature shift factor was calculated for the adhesive. The relaxation spectrum also showed a strong correlation with swelling of the adhesive and the pH. The influence of these two parameters were captured into the model based on the relaxation time parameter in the Prony series approach. Based on this study the impact of these parameters could be appreciated on the performance and mechanical behavior of denture adhesives and implemented into a Prony series based viscoelastic material model which can be used with numerical simulations.
  • Thumbnail Image
    ItemOpen Access
    Analysing the bone cement flow in the injection apparatus during vertebroplasty
    (2023) Trivedi, Zubin; Gehweiler, Dominic; Wychowaniec, Jacek K.; Ricken, Tim; Gueorguiev-Rüegg, Boyko; Wagner, Arndt; Röhrle, Oliver
    Vertebroplasty, a medical procedure for treating vertebral fractures, requires medical practitioners to inject bone cement inside the vertebra using a cannula attached to a syringe. The required injection force must be small enough for the practitioner to apply it by hand while remaining stable for a controlled injection. Several factors could make the injection force unintuitive for the practitioners, one of them being the non‐Newtonian nature of the bone cement. The viscosity of the bone cement varies as it flows through the different parts of the injection apparatus and the porous cancellous interior of the vertebra. Therefore, it is important to study the flow of bone cement through these parts. This work is a preliminary study on the flow of bone cement through the injection apparatus. Firstly, we obtained the rheological parameters for the power law model of bone cement using experiments using standard clinical equipment. These parameters were then used to obtain the shear rate, viscosity, and velocity profiles of the bone cement flow through the cannula. Lastly, an analysis was carried out to understand the influence of various geometrical parameters of the injection apparatus, in which the radius of the cannula was found to be the most influential parameter.