02 Fakultät Bau- und Umweltingenieurwissenschaften

Permanent URI for this collectionhttps://elib.uni-stuttgart.de/handle/11682/3

Browse

Search Results

Now showing 1 - 10 of 19
  • Thumbnail Image
    ItemOpen Access
    Linking cortex and contraction : integrating models along the corticomuscular pathway
    (2023) Haggie, Lysea; Schmid, Laura; Röhrle, Oliver; Besier, Thor; McMorland, Angus; Saini, Harnoor
    Computational models of the neuromusculoskeletal system provide a deterministic approach to investigate input-output relationships in the human motor system. Neuromusculoskeletal models are typically used to estimate muscle activations and forces that are consistent with observed motion under healthy and pathological conditions. However, many movement pathologies originate in the brain, including stroke, cerebral palsy, and Parkinson’s disease, while most neuromusculoskeletal models deal exclusively with the peripheral nervous system and do not incorporate models of the motor cortex, cerebellum, or spinal cord. An integrated understanding of motor control is necessary to reveal underlying neural-input and motor-output relationships. To facilitate the development of integrated corticomuscular motor pathway models, we provide an overview of the neuromusculoskeletal modelling landscape with a focus on integrating computational models of the motor cortex, spinal cord circuitry, α-motoneurons  and skeletal muscle in regard to their role in generating voluntary muscle contraction. Further, we highlight the challenges and opportunities associated with an integrated corticomuscular pathway model, such as challenges in defining neuron connectivities, modelling standardisation, and opportunities in applying models to study emergent behaviour. Integrated corticomuscular pathway models have applications in brain-machine-interaction, education, and our understanding of neurological disease.
  • Thumbnail Image
    ItemOpen Access
    Determination of muscle shape deformations of the tibialis anterior during dynamic contractions using 3D ultrasound
    (2024) Sahrmann, Annika S.; Vosse, Lukas; Siebert, Tobias; Handsfield, Geoffrey G.; Röhrle, Oliver
    Purpose: In this paper, we introduce a novel method for determining 3D deformations of the human tibialis anterior (TA) muscle during dynamic movements using 3D ultrasound. Materials and Methods: An existing automated 3D ultrasound system is used for data acquisition, which consists of three moveable axes, along which the probe can move. While the subjects perform continuous plantar- and dorsiflexion movements in two different controlled velocities, the ultrasound probe sweeps cyclically from the ankle to the knee along the anterior shin. The ankle joint angle can be determined using reflective motion capture markers. Since we considered the movement direction of the foot, i.e., active or passive TA, four conditions occur: slow active, slow passive, fast active, fast passive. By employing an algorithm which defines ankle joint angle intervals, i.e., intervals of range of motion (ROM), 3D images of the volumes during movement can be reconstructed. Results: We found constant muscle volumes between different muscle lengths, i.e., ROM intervals. The results show an increase in mean cross-sectional area (CSA) for TA muscle shortening. Furthermore, a shift in maximum CSA towards the proximal side of the muscle could be observed for muscle shortening. We found significantly different maximum CSA values between the fast active and all other conditions, which might be caused by higher muscle activation due to the faster velocity. Conclusion: In summary, we present a method for determining muscle volume deformation during dynamic contraction using ultrasound, which will enable future empirical studies and 3D computational models of skeletal muscles.
  • Thumbnail Image
    ItemOpen Access
    Variations in muscle activity and exerted torque during temporary blood flow restriction in healthy individuals
    (2021) Gizzi, Leonardo; Yavuz, Utku Ş.; Hillerkuss, Dominic; Geri, Tommaso; Gneiting, Elena; Domeier, Franziska; Schmitt, Syn; Röhrle, Oliver
    Recent studies suggest that transitory blood flow restriction (BFR) may improve the outcomes of training from anatomical (hypertrophy) and neural control perspectives. Whilst the chronic consequences of BFR on local metabolism and tissue adaptation have been extensively investigated, its acute effects on motor control are not yet fully understood. In this study, we compared the neuromechanical effects of continuous BFR against non-restricted circulation (atmospheric pressure-AP), during isometric elbow flexions. BFR was achieved applying external pressure either between systolic and diastolic (lower pressure-LP) or 1.3 times the systolic pressure (higher pressure-HP). Three levels of torque (15, 30, and 50% of the maximal voluntary contraction-MVC) were combined with the three levels of pressure for a total of 9 (randomized) test cases. Each condition was repeated 3 times. The protocol was administered to 12 healthy young adults. Neuromechanical measurements (torque and high-density electromyography-HDEMG) and reported discomfort were used to investigate the response of the central nervous system to BFR. The investigated variables were: root mean square (RMS), and area under the curve in the frequency domain-for the torque, and average RMS, median frequency and average muscle fibres conduction velocity-for the EMG. The discomfort caused by BFR was exacerbated by the level of torque and accumulated over time. The torque RMS value did not change across conditions and repetitions. Its spectral content, however, revealed a decrease in power at the tremor band (alpha-band, 5-15 Hz) which was enhanced by the level of pressure and the repetition number. The EMG amplitude showed no differences whilst the median frequency and the conduction velocity decreased over time and across trials, but only for the highest levels of torque and pressure. Taken together, our results show strong yet transitory effects of BFR that are compatible with a motor neuron pool inhibition caused by increased activity of type III and IV afferences, and a decreased activity of spindle afferents. We speculate that a compensation of the central drive may be necessary to maintain the mechanical output unchanged, despite disturbances in the afferent volley to the motor neuron pool.
  • Thumbnail Image
    ItemOpen Access
    Editorial - somatosensory integration in human movement : perspectives for neuromechanics, modelling and rehabilitation
    (2021) Gizzi, Leonardo; Vujaklija, Ivan; Sartori, Massimo; Röhrle, Oliver; Severini, Giacomo
  • Thumbnail Image
    ItemOpen Access
    A physiology-guided classification of active-stress and active-strain approaches for continuum-mechanical modeling of skeletal muscle tissue
    (2021) Klotz, Thomas; Bleiler, Christian; Röhrle, Oliver
    The well-established sliding filament and cross-bridge theory explain the major biophysical mechanism responsible for a skeletal muscle's active behavior on a cellular level. However, the biomechanical function of skeletal muscles on the tissue scale, which is caused by the complex interplay of muscle fibers and extracellular connective tissue, is much less understood. Mathematical models provide one possibility to investigate physiological hypotheses. Continuum-mechanical models have hereby proven themselves to be very suitable to study the biomechanical behavior of whole muscles or entire limbs. Existing continuum-mechanical skeletal muscle models use either an active-stress or an active-strain approach to phenomenologically describe the mechanical behavior of active contractions. While any macroscopic constitutive model can be judged by it's ability to accurately replicate experimental data, the evaluation of muscle-specific material descriptions is difficult as suitable data is, unfortunately, currently not available. Thus, the discussions become more philosophical rather than following rigid methodological criteria. Within this work, we provide a extensive discussion on the underlying modeling assumptions of both the active-stress and the active-strain approach in the context of existing hypotheses of skeletal muscle physiology. We conclude that the active-stress approach resolves an idealized tissue transmitting active stresses through an independent pathway. In contrast, the active-strain approach reflects an idealized tissue employing an indirect, coupled pathway for active stress transmission. Finally the physiological hypothesis that skeletal muscles exhibit redundant pathways of intramuscular stress transmission represents the basis for considering a mixed-active-stress-active-strain constitutive framework.
  • Thumbnail Image
    ItemOpen Access
    Numerical study of the stress state on the oral mucosa and abutment tooth upon insertion of partial dentures in the mandible
    (2022) Ramakrishnan, Anantha Narayanan; Röhrle, Oliver; Ludtka, Christopher; Varghese, Roshan; Koehler, Josephine; Kiesow, Andreas; Schwan, Stefan
    The introduction of a removable partial denture onto the dental arch significantly influences the mechanical stress characteristics of both the jawbone and oral mucosa. The aim of this study was to analyze the stress state caused by biting forces upon insertion of partial dentures into the assembly, and to understand the influence of the resulting contact pressure on its retention behavior. For this purpose, a numerical model of a removable partial denture is proposed based on 3D models developed using computer tomography data of the jawbone and the removable partial denture. The denture system rests on the oral mucosa surface and three abutment teeth. The application of bite forces on the denture generated a stick condition on the loaded regions of the denture‐oral mucosa interface, which indicates positive retention of the denture onto the oral mucosa surface. Slip and negative retention were observed in the regions of the contact space that were not directly loaded. The contact pressures observed in the regions of the oral mucosa in contact with the denture were below the clinical pressure pain threshold value for soft tissue, which potentially lowers the risk of pain being experienced by denture users. Further, the variation of the retention behavior and contact pressures across different regions of the denture assembly was observed. Thus, there is a need for adhesives or restraining mechanisms for the denture system in order to avoid bending and deformation of sections of the denture as a consequence of the applied bite force.
  • Thumbnail Image
    ItemOpen Access
    A microstructurally-based, multi-scale, continuum-mechanical model of skeletal muscle tissue
    (2019) Bleiler, Christian; Ponte Castañeda, Pedro; Röhrle, Oliver
  • Thumbnail Image
    ItemOpen Access
    Mapping the role of oral cavity physiological factors into the viscoelastic model of denture adhesives for numerical implementation
    (2023) Ramakrishnan, Anantha Narayanan; Röhrle, Oliver; Ludtka, Christopher; Koehler, Josephine; Kiesow, Andreas; Schwan, Stefan
    Physiological parameters of the oral cavity have a profound impact on any restorative solutions designed for edentulous patients including denture adhesives. This study aims to mathematically quantify the influence of three such variables, namely: the temperature, pH, and the swelling of such adhesives under the influence of saliva on its mechanical behavior. The mathematical quantification is further aimed to implement a material model for such adhesives which considers the impact of such physiological factors. The denture adhesive is experimentally investigated by means of rheological steady state frequency sweep tests to obtain the relaxation spectrum of the material. The relaxation behavior is measured for a wide range of oral cavity temperatures and pH. Also, the adhesive is hydrated and upon swelling to different levels again tested to understand the impact of swelling on the mechanical behavior. The experimentally measured continuous relaxation spectrum is modeled as a viscoelastic material using a discrete set of points based on the Prony series discretization technique. The relaxation spectrums for various temperatures are compared and the possibility of a time-temperature superposition is explored for the model. Similarly, the measured values of Storage and loss modulus are investigated to understand the role of pH and swelling. The results in this study clearly indicated a horizontal shift in the relaxation behavior with increase in temperature. And hence, the time-temperature shift factor was calculated for the adhesive. The relaxation spectrum also showed a strong correlation with swelling of the adhesive and the pH. The influence of these two parameters were captured into the model based on the relaxation time parameter in the Prony series approach. Based on this study the impact of these parameters could be appreciated on the performance and mechanical behavior of denture adhesives and implemented into a Prony series based viscoelastic material model which can be used with numerical simulations.
  • Thumbnail Image
    ItemOpen Access
    Analysing the bone cement flow in the injection apparatus during vertebroplasty
    (2023) Trivedi, Zubin; Gehweiler, Dominic; Wychowaniec, Jacek K.; Ricken, Tim; Gueorguiev-Rüegg, Boyko; Wagner, Arndt; Röhrle, Oliver
    Vertebroplasty, a medical procedure for treating vertebral fractures, requires medical practitioners to inject bone cement inside the vertebra using a cannula attached to a syringe. The required injection force must be small enough for the practitioner to apply it by hand while remaining stable for a controlled injection. Several factors could make the injection force unintuitive for the practitioners, one of them being the non‐Newtonian nature of the bone cement. The viscosity of the bone cement varies as it flows through the different parts of the injection apparatus and the porous cancellous interior of the vertebra. Therefore, it is important to study the flow of bone cement through these parts. This work is a preliminary study on the flow of bone cement through the injection apparatus. Firstly, we obtained the rheological parameters for the power law model of bone cement using experiments using standard clinical equipment. These parameters were then used to obtain the shear rate, viscosity, and velocity profiles of the bone cement flow through the cannula. Lastly, an analysis was carried out to understand the influence of various geometrical parameters of the injection apparatus, in which the radius of the cannula was found to be the most influential parameter.