07 Fakultät Konstruktions-, Produktions- und Fahrzeugtechnik

Permanent URI for this collectionhttps://elib.uni-stuttgart.de/handle/11682/8

Browse

Search Results

Now showing 1 - 2 of 2
  • Thumbnail Image
    ItemOpen Access
    Miniature low-cost γ-radiation sensor for localization of radioactively marked lymph nodes
    (2022) Behling, Merlin; Wezel, Felix; Pott, Peter P.
    Detection of metastasis spread at an early stage of disease in lymph nodes can be achieved by imaging techniques, such as PET and fluoride-marked tumor cells. Intraoperative detection of small metastasis can be problematic especially in minimally invasive surgical settings. A γ-radiation sensor can be inserted in the situs to facilitate intraoperative localization of the lymph nodes. In the minimally invasive setting, the sensor must fit through the trocar and for robot-aided interventions, a small, capsule-like device is favorable. Size reduction could be achieved by using only a few simple electronic parts packed in a single-use sensor-head also leading to a low-cost device. This paper first describes the selection of an appropriate low-cost diode, which is placed in a sensor head (Ø 12 mm) and characterized in a validation experiment. Finally, the sensor and its performance during a detection experiment with nine subjects is evaluated. The subjects had to locate a 137Cs source (138 kBq activity, 612 keV) below a wooden plate seven times. Time to accomplish this task and error rate were recorded and evaluated. The time needed by the subjects to complete each run was 95 ± 68.1 s for the first trial down to 40 ± 23.9 s for the last. All subjects managed to locate the 137Cs source precisely. Further reduction in size and a sterilizable housing are prerequisites for in vitro tests on explanted human lymph nodes and finally in vivo testing.
  • Thumbnail Image
    ItemOpen Access
    Design and evaluation of new user control devices for improved ergonomics in flexible robotic endoscopy
    (2025) Heisterberg, Leander; Manfredi, Luigi; Wichmann, Dörte; Maier, Thomas; Pott, Peter P.
    Background: The ergonomics of flexible endoscopes require improvement as the current design carries a high risk of musculoskeletal injury for endoscopists. Robotic systems offer a solution by separating the endoscope from the control handle, allowing a focus on ergonomics and usability. Despite the increasing interest in this field, little attention has been paid towards developing ergonomic human input devices. This study addresses two key questions: How can handheld control devices for flexible robotic endoscopy be designed to prioritize ergonomics and usability? And, how effective are these new devices in a simulated clinical environment?
    Methods: Addressing this gap, the study proposes two handheld input device models for controlling a flexible endoscope in four degrees of freedom (DOFs) and an endoscopic instrument in three DOFs. A two-stage evaluation was conducted with six endoscopists evaluating the physical ergonomics and a final clinical user evaluation with seven endoscopists using a virtual colonoscopy simulator with proportional velocity and position mapping.
    Results and discussion: Both models demonstrated clinical suitability, with the first model scoring 4.8 and the second model scoring 5.2 out of 6 in the final evaluation. In sum, the study presents two designs of ergonomic control devices for robotic colonoscopy, which have the potential to reduce endoscopy-related injuries. Furthermore, the proposed colonoscopy simulator is useful to evaluate the benefits of different mapping modes. This could help to optimize the design and control mechanism of future control devices.