Influence of edge proximity on concrete breakout failure in post-installed RC columns foundation joints

dc.contributor.authorCattaneo, Sara
dc.contributor.authorMahadik, Vinay
dc.contributor.authorGenesio, Giovacchino
dc.contributor.authorHofmann, Jan
dc.date.accessioned2024-11-27T15:19:20Z
dc.date.available2024-11-27T15:19:20Z
dc.date.issued2023de
dc.date.updated2024-11-02T08:50:36Z
dc.description.abstractThis paper discusses findings from an experimental program aimed at investigation of concrete breakout failure within the rebar end anchorage zone of reinforced concrete column-to-foundation joints, with columns located in proximity of foundation edge/s. A total of four tests on full scale column foundation joints are presented. In all specimens the column main reinforcement is anchored in the foundation using post-installed rebar technology. All connections are designed with the objective to trigger concrete breakout failure mode within the rebar end anchorage zone. Finite element analyses were used as a tool to design the specimens. The paper presents discussion of the test results within the framework of expectations outlaid during design of the test specimens. The effects of bending compression from column on the concrete breakout capacity under influence of foundation edges is the specific focus of the present investigation. It is shown that the direction of application of load on the column largely determines the effect of bending compression from column on concrete breakout capacity. The test data presented in this paper offers the necessary benchmark data on concrete breakout behavior in the case of reinforced concrete column foundation joints under influence of foundation edges. This test data along with insights from finite element analyses is employed to explore and possibly identify necessary modifications to the current state-of-the-art consideration of concrete breakout capacity for reinforced concrete connections.en
dc.description.sponsorshipProjekt DEALde
dc.description.sponsorshipUniversität Stuttgartde
dc.identifier.issn1871-6873
dc.identifier.issn1359-5997
dc.identifier.other1913631028
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-153488de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/15348
dc.identifier.urihttp://dx.doi.org/10.18419/opus-15329
dc.language.isoende
dc.relation.uridoi:10.1617/s11527-023-02208-7de
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/de
dc.subject.ddc624de
dc.titleInfluence of edge proximity on concrete breakout failure in post-installed RC columns foundation jointsen
dc.typearticlede
ubs.fakultaetBau- und Umweltingenieurwissenschaftende
ubs.fakultaetFakultätsübergreifend / Sonstige Einrichtungde
ubs.institutInstitut für Werkstoffe im Bauwesende
ubs.institutFakultätsübergreifend / Sonstige Einrichtungde
ubs.publikation.seiten18de
ubs.publikation.sourceMaterials and structures 56 (2023), No. 119de
ubs.publikation.typZeitschriftenartikelde

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
s11527-023-02208-7.pdf
Size:
2.7 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.3 KB
Format:
Item-specific license agreed upon to submission
Description: