dc.description.abstractThe flow field induced by the release of compressed air in a water body has been studied analytically and experimentally. The quantitative knowledge of the flow pattern in standing water and in a cross flow serves as a basis for the design of air bubble installations, which can be used advantageously for a number of purposes in water quality control, such as pneumatic oil barriers, barriers against density currents due to differences in salinity, silt or sediment concentration or temperature, installations for combating the formation of ice, artificial destratification devices or installations for oxygenation purposes.en
dc.identifier.other423628704de
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-97722de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/8297
dc.identifier.urihttp://dx.doi.org/10.18419/opus-8280
dc.language.isoende
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.subject.classificationLuftschleieranlage , Wassergütede
dc.subject.ddc333.7de
dc.titleAir bubble screens as a tool for water quality controlen
dc.typeconferenceObjectde
ubs.fakultaetFakultätsübergreifend / Sonstige Einrichtungde
ubs.institutSonstige Einrichtungde
ubs.opusid9772de
ubs.publikation.sourceVarma, Chelikani (Hrsg.): Water for human needs : proceedings of the Second World Congress on Water Resources, New Delhi, India, 12-16 December 1975. Vol. 2 : Health and planning. New Delhi : Varma, 1976, S. 163-171de
ubs.publikation.typKonferenzbeitragde

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
kob99.pdf
Size:
4.15 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1021 B
Format:
Plain Text
Description: