Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: http://dx.doi.org/10.18419/opus-14048
Langanzeige der Metadaten
DC ElementWertSprache
dc.contributor.authorSchalk, Marco-
dc.contributor.authorSchalk, Ines-
dc.contributor.authorBauernhansl, Thomas-
dc.contributor.authorSiegert, Jörg-
dc.contributor.authorSchneider, Urs-
dc.date.accessioned2024-03-13T13:51:19Z-
dc.date.available2024-03-13T13:51:19Z-
dc.date.issued2022de
dc.identifier.issn2673-3846-
dc.identifier.other1883456517-
dc.identifier.urihttp://nbn-resolving.de/urn:nbn:de:bsz:93-opus-ds-140678de
dc.identifier.urihttp://elib.uni-stuttgart.de/handle/11682/14067-
dc.identifier.urihttp://dx.doi.org/10.18419/opus-14048-
dc.description.abstractThis study aims to assess the whole-body physiological effects of wearing an exoskeleton during a one-hour standardized work task, utilizing the Cardiac Index (CI) as the target parameter. N = 42 young and healthy subjects with welding experience took part in the study. The standardized and abstracted one-hour workflow consists of simulated welding and grinding in constrained body positions and was completed twice by each subject, with and without an exoskeleton, in a randomized order. The CI was measured by Impedance Cardiography (ICG), an approved medical method. The difference between the averaged baseline measurement and the averaged last 10 min was computed for the conditions with and without an exoskeleton for each subject to result in ∆CIwithout exo and ∆CIwith exo. A significant difference between the conditions with and without an exoskeleton was found, with the reduction in CI when wearing an exoskeleton amounting to 10.51%. This result corresponds to that of previous studies that analyzed whole-body physiological load by means of spiroergometry. These results suggest a strong positive influence of exoskeletons on CI and, therefore, physiological load. At the same time, they also support the hypothesis that ICG is a suitable measurement instrument to assess these effects.en
dc.description.sponsorshipDeutsche Forschungsgemeinschaft (DFG, German Research Foundation)de
dc.description.sponsorshipUniversity of Stuttgart IFF and Fraunhofer IPA, Stuttgartde
dc.language.isoende
dc.relation.uridoi:10.3390/hearts3040014de
dc.rightsinfo:eu-repo/semantics/openAccessde
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/de
dc.subject.ddc670de
dc.titleInfluence of exoskeleton use on Cardiac Indexen
dc.typearticlede
dc.date.updated2023-11-14T00:11:32Z-
ubs.fakultaetKonstruktions-, Produktions- und Fahrzeugtechnikde
ubs.fakultaetExterne wissenschaftliche Einrichtungende
ubs.institutInstitut für Industrielle Fertigung und Fabrikbetriebde
ubs.institutFraunhofer Institut für Produktionstechnik und Automatisierung (IPA)de
ubs.publikation.seiten117-128de
ubs.publikation.sourceHearts 3 (2022), S. 117-128de
ubs.publikation.typZeitschriftenartikelde
Enthalten in den Sammlungen:07 Fakultät Konstruktions-, Produktions- und Fahrzeugtechnik

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
hearts-03-00014-v2.pdf2,69 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons